Ultrasonic fingerprint fitting(QTH2000)

This equipment is used for the fully automatic full lamination process of smart wearable products;

Ultrasonic fingerprint fitting(QTH2000)
Technical parameters
  • Name

    Ultrasonic fingerprint fitting(QTH2000)

  • Product Size(OLED)

    4.5-7.5寸

  • Tray Size

    MAX:300*220~400*400mm
    3.SENSOR/OLEDOpening area size

  • SENSOR/OLEDOpening area size

    AA outer contour size, 4*4~40*40mm, excluding FPC size, MAX: 100mm, orientation unspecified, 5*5~42*42mm

  • Film retrieval accuracy

    ±0.2mm

  • Pick-and-place discarding rate

    ≤0.03%

  • Cleaning Method

    Cleaning with a lint-free cloth + PLASMA.

  • Adhesion Accuracy

    ≤±0.1mm CPK≥1.33

  • Adhesion yield

    99.7%

  • Conformal pressure:

    1.Conform to pressure specifications 20~500N
    2.Pressure accuracy: 10~50N ± 1N 50~500N±2N

  • Pressure control

    0.1-0.5Mpa

  • Repeatability accuracy of equipment

    Key fit axis repeatability≤0.01mm CMK1.67

  • Failure rate

    ≤3% (Failure time / Total operation time * 100%) with an average auxiliary interval time ≥2H (minor failure) and MTBF ≤168

  • TT time

    3.6S (with 4*4mm 7-inch OLED ≤ 1000 PCS/H, bonding and pressure maintaining time is 5S), normal production capacity is 800-1000 PCS/H

  • Dust-free level of equipment:

    Static Class 100 dust prevention, equipped with FFU and ionizing bar, with the distance between the FFU air outlet and the product being ≥800mm. All large boards and above adopt Teflon dust-proof drag chains, and all high-flex cables use IGUS

  • Device model

    Fully automatic vacuum laminating machine

  • Machine size

    18000 (L)x23000 (W)x2200 (H) mm

  • Power supply

    AC220V/50Hz

  • Gas source

    0.4一0.7MPa、dry

  • Vacuum Source

    0-99kPa

  • Environmental Requirements

    Clean room